工程機械電器設備出現故障後,應采取科學、便捷、準確、安全的方法進行診斷,並應遵循必要的檢修原則,具體如下所述。
一、診斷方法
1、直觀檢查法
此方法不使用任何儀器設備,不改變電路接線,隻根據電器故障的外部表現,憑視覺、聽覺、嗅覺和觸覺等手段,直接觀察、jianzhahepanduanguzhang。shijianzhengming,dianqishebeideduoshuguzhangkeyongzhiguanjianzhafalaifaxianqiguzhangdian,yinciduidianqishebeiguzhangdejianxiuyingshouxianshiyongzhiguanjianzhafa。zhiguanjianzhafakecaiyongbutongdianguanchafahetongdianguanchafa。
zaifaxianguzhanghoujinxingdianqiyuanjianxiulishi,bunengzhigenghuanyisunhuaideyuanqijian,yinggenjudianluyuanlifenxibingzhazhaodaozhiguzhangchanshengdezhenzhengyuanyinyijiliandaisunhuaideqitayuanqijian。fouze,zhenzhengdeguzhangyinsumeipaichu,shebeikaijishiyonghou,genghuandeyuanqijianyouhuisunhuai。
2、對比檢查法
cifangfashibajianceshujuyutuzhiziliaojiyunzhuanjiludecanshuxiangbijiaolaipanduanguzhang。duiwuziliaoyouwuyunzhuanjiludedianqishebei,keyutongxinghaowanhaodedianqishebeixiangbijiao。dianluzhongdedianqiyuanjianshuyutongyangkongzhigongnenghuoduogeyuanjiangongtongkongzhitongyishebeishi,keyiliyongqitaxiangsidehuotongyidianyuandeyuanjiandongzuoqingkuanglaipanduanguzhang。
3、電壓檢測法
電壓檢測法不僅包括檢查電器設備的各種電源電壓,還包括各級電子管、晶jing體ti管guan及ji集ji成cheng電dian路lu的de靜jing態tai電dian位wei。該gai方fang法fa根gen據ju電dian器qi的de供gong電dian方fang式shi,檢jian測ce各ge點dian的de電dian壓ya值zhi與yu電dian流liu值zhi並bing與yu正zheng常chang值zhi比bi較jiao,以yi判pan斷duan故gu障zhang點dian。進jin行xing故gu障zhang檢jian查zha時shi,應ying先xian測ce量liang電dian壓ya是shi否fou正zheng常chang,即ji使shi已yi經jing確que定ding了le故gu障zhang所suo在zai的de電dian路lu部bu位wei,也ye需xu要yao測ce量liang電dian路lu中zhong各ge關guan鍵jian點dian的de電dian壓ya是shi否fou正zheng常chang,這zhe對dui於yu發fa現xian損sun壞huai的de元yuan器qi件jian和he分fen析xi故gu障zhang的de原yuan因yin,都dou是shi極ji有you幫bang助zhu的de。
此(ci)外(wai),對(dui)電(dian)路(lu)中(zhong)電(dian)流(liu)的(de)測(ce)量(liang),往(wang)往(wang)也(ye)采(cai)用(yong)測(ce)量(liang)有(you)關(guan)電(dian)阻(zu)兩(liang)端(duan)電(dian)壓(ya)降(jiang)再(zai)用(yong)歐(ou)姆(mu)定(ding)律(lv)進(jin)行(xing)換(huan)算(suan)的(de)方(fang)法(fa)。將(jiang)測(ce)量(liang)值(zhi)與(yu)電(dian)路(lu)電(dian)壓(ya)正(zheng)常(chang)值(zhi)進(jin)行(xing)比(bi)較(jiao),可(ke)以(yi)很(hen)快(kuai)發(fa)現(xian)損(sun)壞(huai)的(de)元(yuan)器(qi)件(jian)和(he)查(zha)明(ming)故(gu)障(zhang)的(de)原(yuan)因(yin)。
4、電阻測量法
在許多情況下,故障發生後機器不能繼續通電,即電流、電壓、波形等均無法測量,而電阻測量法卻非常適用。元件損壞、變質以及連接導線短路、斷路、接地不良等故障,利用電流、電壓、波形方法一般隻能確定大致的部位,而最後找出故障點仍需經過電阻測量法。
在zai進jin行xing電dian阻zu測ce量liang時shi,應ying注zhu意yi並bing聯lian電dian路lu的de影ying響xiang,即ji在zai測ce量liang單dan個ge電dian阻zu時shi,如ru果guo還hai有you並bing聯lian電dian阻zu,應ying將jiang其qi斷duan開kai。在zai測ce量liang較jiao大da的de電dian阻zu時shi,不bu要yao將jiang兩liang手shou捏nie在zai表biao筆bi的de裸luo露lu部bu分fen而er造zao成cheng測ce量liang誤wu差cha。在zai用yong兆zhao歐ou表biao檢jian查zha電dian路lu及ji電dian動dong機ji、電(dian)纜(lan)的(de)絕(jue)緣(yuan)電(dian)阻(zu)值(zhi)時(shi),應(ying)注(zhu)意(yi)其(qi)工(gong)作(zuo)電(dian)壓(ya)不(bu)能(neng)超(chao)過(guo)電(dian)路(lu)中(zhong)有(you)關(guan)零(ling)件(jian)的(de)耐(nai)壓(ya),以(yi)防(fang)被(bei)擊(ji)穿(chuan),造(zao)成(cheng)不(bu)應(ying)有(you)損(sun)壞(huai)。在(zai)對(dui)串(chuan)有(you)電(dian)表(biao)或(huo)尚(shang)未(wei)放(fang)電(dian)完(wan)畢(bi)的(de)電(dian)容(rong)器(qi)的(de)電(dian)路(lu)進(jin)行(xing)電(dian)阻(zu)測(ce)量(liang)時(shi),應(ying)特(te)別(bie)注(zhu)意(yi)測(ce)量(liang)安(an)全(quan)。
5、短接試驗法
即選用1根(gen)絕(jue)緣(yuan)良(liang)好(hao)的(de)導(dao)線(xian),將(jiang)所(suo)懷(huai)疑(yi)的(de)斷(duan)路(lu)部(bu)位(wei)短(duan)路(lu),如(ru)短(duan)接(jie)到(dao)某(mou)處(chu),電(dian)路(lu)恢(hui)複(fu)正(zheng)常(chang),說(shuo)明(ming)被(bei)短(duan)路(lu)部(bu)位(wei)斷(duan)路(lu)。具(ju)體(ti)操(cao)作(zuo)時(shi)可(ke)采(cai)取(qu)局(ju)部(bu)短(duan)接(jie)法(fa)和(he)長(chang)路(lu)短(duan)接(jie)法(fa)。
6、電容旁路法
即使用1個適當容量和耐壓的電容器,跨接在有疑問電路的輸入端,使之對“地”相xiang通tong,以yi觀guan察cha對dui故gu障zhang現xian象xiang的de影ying響xiang。如ru果guo故gu障zhang消xiao失shi,表biao明ming故gu障zhang存cun在zai於yu前qian麵mian各ge級ji電dian路lu中zhong,反fan之zhi則ze表biao明ming故gu障zhang存cun在zai於yu本ben級ji以yi後hou的de電dian路lu中zhong。隻zhi要yao往wang前qian或huo往wang後hou依yi次ci使shi用yong此ci法fa,便bian可ke確que定ding故gu障zhang存cun在zai的de部bu位wei。
7、斷路試驗法
斷duan路lu試shi驗yan法fa就jiu是shi斷duan開kai電dian路lu連lian接jie的de一yi端duan,或huo者zhe取qu下xia所suo懷huai疑yi的de元yuan件jian,觀guan測ce對dui故gu障zhang現xian象xiang的de影ying響xiang,如ru果guo故gu障zhang消xiao失shi,則ze被bei斷duan開kai電dian路lu或huo取qu下xia的de元yuan件jian可ke能neng有you故gu障zhang。這zhe種zhong方fang法fa適shi用yong於yu檢jian查zha直zhi流liu供gong電dian電dian源yuan短duan路lu或huo因yin負fu載zai過guo重zhong造zao成cheng元yuan器qi件jian損sun壞huai等deng故gu障zhang。若ruo待dai測ce電dian路lu比bi較jiao複fu雜za、涉及元器件較多並且互相牽製時,隻要其中一個單元電路有故障,就會牽連整個電路的工作,此時采用“斷路試驗法”每切斷一點,就能確定電路的一半是否有故障。
8、逐步開路法
遇yu到dao難nan以yi檢jian查zha的de短duan路lu或huo接jie地di故gu障zhang,可ke重zhong新xin更geng換huan熔rong斷duan器qi,將jiang各ge支zhi路lu逐zhu個ge或huo有you重zhong點dian地di從cong電dian路lu中zhong斷duan開kai,然ran後hou通tong電dian試shi驗yan,若ruo熔rong斷duan器qi一yi再zai熔rong斷duan,表biao明ming故gu障zhang就jiu在zai剛gang剛gang斷duan開kai的de這zhe條tiao電dian路lu上shang。然ran後hou再zai將jiang該gai支zhi路lu分fen成cheng幾ji段duan,逐zhu段duan接jie入ru電dian路lu。當dang接jie入ru某mou段duan電dian路lu時shi熔rong斷duan器qi又you熔rong斷duan,表biao明ming故gu障zhang點dian就jiu在zai這zhe段duan電dian路lu及ji某mou電dian器qi元yuan件jian上shang。
9、逐步接入法
即ji在zai電dian路lu出chu現xian短duan路lu或huo接jie地di故gu障zhang時shi,換huan上shang新xin熔rong斷duan器qi後hou將jiang各ge支zhi路lu逐zhu條tiao或huo有you選xuan擇ze地di接jie入ru電dian源yuan,重zhong新xin試shi驗yan。若ruo接jie到dao某mou段duan時shi熔rong斷duan器qi又you熔rong斷duan,表biao明ming故gu障zhang就jiu在zai剛gang剛gang接jie入ru的de這zhe條tiao電dian路lu及ji其qi所suo包bao含han的de電dian器qi元yuan件jian上shang。
10、強迫閉合法
即采用1絕緣棒將有關繼電器、接觸器、diancitiedengshijiawaili,shiqichangkaichudianbihe,ranhouguanchadianqibufenhuojixiebufenchuxiandegezhongxianxiang,rudiandongjicongbuzhuandongdaozhuandong,shebeixiangyingdebufencongbuyunxingdaozhengchangyunxingdeng。
11、波形測量法
可使用示波器通過查明電路的波形是否正常來發現電路故障。用示波器對電路各級輸入、輸(shu)出(chu)波(bo)形(xing)進(jin)行(xing)觀(guan)察(cha),往(wang)往(wang)可(ke)以(yi)迅(xun)速(su)發(fa)現(xian)故(gu)障(zhang)部(bu)位(wei)。檢(jian)查(zha)時(shi),由(you)前(qian)級(ji)向(xiang)後(hou)級(ji)推(tui)移(yi),直(zhi)至(zhi)發(fa)現(xian)某(mou)一(yi)級(ji)輸(shu)出(chu)波(bo)形(xing)不(bu)正(zheng)常(chang),則(ze)可(ke)確(que)定(ding)故(gu)障(zhang)原(yuan)因(yin)存(cun)在(zai)於(yu)這(zhe)一(yi)級(ji)電(dian)路(lu)中(zhong)。
12、轉換元件法
mouxiedianludeguzhangyuanyinbuyizhaming,danghuaiyimouyibujianhuomouyiyuanjianyouguzhangshi,keshiyongwanhaodetongxinghaobujianhuoyuanjianhuhuanhoujinxingbijiao,yizhengshiguzhangshifouyouciyinqi。ruohuhuanhougongzuozhengchang,zekequedingguzhangfashengzaihuanxiadebujianhuoyuanjianshang。youshigandaoguzhangxianxianghenfuza,shenzhinanyixiashou,yongzhuanhuanyuanjianfaquehenzouxiao。yunyongzhuanhuanyuanjianfajianzhashi,yingzhuyijianzhachaixiadeyuanjianshifouyijingsunhuai,zhiyouquedingyijingsunhuaishi,cainenghuanshangxinyuanjian。
二、檢修原則
1、先判斷再動手
yidandianqishebeichuxianguzhang,bixuxianlejiechanshengguzhangdeqianhoujingguojiguzhangxianxiang,ranhoudongshouweixiu。duiyushengshudedianqishebei,yingxianshuxidianluyuanlihejiegoutedian。chaixieqianyaochongfenshuximeigedianqibujiandegongneng、位置、連接方式及相互關係,在沒有電路圖的情況下,應一邊拆卸,一邊繪製草圖,並記上標記。
2、先外部再內部
電器設備出現故障後,先檢查其有無明顯裂痕、缺損,了解其維修履曆、使用年限等,然後再對其內部進行檢查。拆前應排除外圍故障因素,確定為內部故障後才能拆卸。
3、先機械再電氣
應(ying)在(zai)確(que)定(ding)機(ji)械(xie)零(ling)件(jian)無(wu)故(gu)障(zhang)後(hou),再(zai)進(jin)行(xing)電(dian)器(qi)方(fang)麵(mian)的(de)檢(jian)查(zha)。檢(jian)查(zha)電(dian)路(lu)故(gu)障(zhang)時(shi),應(ying)利(li)用(yong)檢(jian)測(ce)儀(yi)器(qi)判(pan)斷(duan)故(gu)障(zhang)部(bu)位(wei),確(que)認(ren)無(wu)接(jie)觸(chu)不(bu)良(liang)故(gu)障(zhang)後(hou),再(zai)有(you)針(zhen)對(dui)性(xing)地(di)查(zha)看(kan)電(dian)路(lu)與(yu)機(ji)械(xie)的(de)運(yun)動(dong)關(guan)係(xi)。
4、先靜態再動態
在設備未通電時,要先判斷電器設備按鈕、接觸器、熱繼電器以及保險絲等是否正常,從而判定故障的部位所在。然後進行通電試驗,聽聲音,測參數,以判斷故障。
5、先清潔再維修
對汙染較重的電器設備,應先對其按鈕、接線端子、接觸點進行清潔,檢查外部控製是否失靈。許多故障都是由髒汙及導電塵塊引起的,一經清潔,故障往往就會消失。
6、先電源再設備
電源部分的故障在電器設備故障中所占比率很高,所以先檢修電源往往可以起到事半功倍的效果。
7、先直流再交流
先檢查直流回路靜態工作點,再檢查交流回路動態工作點。
8、先排障再調試
對於需要調試並存在故障的電器設備,應先排除故障,再進行調試。調試電器設備則必須在熟悉電路的前提下進行。