jinjiduandiankaiguanzuoweiqizhongjixiezhongyaodedianqibaohuzhuangzhi,zaianquanyunxingzhongqizhefeichangzhongyaodezuoyong。youyujianyanrenyuanduigaikaiguanneihandelijiechengdubutong,yinci,zairichangjianyanguochengzhong,duigaikaiguanshifouhegedepandingbiaozhunyecunzaiyidingdechayi。
《起重機械監督檢驗規程》中規定:“起qi重zhong機ji必bi須xu設she置zhi緊jin急ji斷duan電dian開kai關guan,在zai緊jin急ji情qing況kuang下xia,應ying能neng切qie斷duan起qi重zhong機ji總zong電dian源yuan。緊jin急ji斷duan電dian開kai關guan應ying是shi不bu能neng自zi動dong複fu位wei的de,且qie應ying設she在zai司si機ji操cao作zuo方fang便bian的de地di方fang。”
部分檢驗人員僅僅通過“緊急斷電開關不能自動複位”來lai判pan定ding緊jin急ji斷duan電dian開kai關guan為wei合he格ge。這zhe樣yang的de判pan定ding方fang法fa會hui使shi部bu分fen不bu合he格ge的de緊jin急ji斷duan電dian開kai關guan被bei誤wu判pan為wei合he格ge,從cong而er給gei安an全quan生sheng產chan帶dai來lai隱yin患huan。現xian在zai市shi場chang上shang的de緊jin急ji斷duan電dian開kai關guan結jie構gou多duo種zhong多duo樣yang,鎖suo定ding及ji複fu位wei的de方fang式shi也ye不bu盡jin相xiang同tong。因yin此ci,對dui緊jin急ji斷duan電dian開kai關guan合he格ge與yu否fou的de判pan斷duan除chu了le滿man足zu能neng否fou自zi動dong複fu位wei的de要yao求qiu外wai,還hai應ying對dui照zhao相xiang關guan國guo家jia標biao準zhun,檢jian驗yan其qi複fu位wei方fang式shi及ji相xiang關guan要yao求qiu。
GB16754-1997《機械安全急停設計原則》第4.4.4款規定:“操作急停裝置產生急停指令後,該指令必須通過驅動裝置的齧合(鎖定)而保持,直到急停裝置的重調(脫開)。”第4.4.5款規定:“急停裝置的重調(脫開)應隻可能在急停裝置上通過手動進行。重調急停裝置時不得由其自身產生再起動指令。”
1.正確的檢驗順序和方法
(1)對(dui)每(mei)個(ge)操(cao)縱(zong)控(kong)製(zhi)點(dian)進(jin)行(xing)檢(jian)驗(yan),尤(you)其(qi)是(shi)雙(shuang)控(kong)製(zhi)係(xi)統(tong)的(de),各(ge)控(kong)製(zhi)係(xi)統(tong)除(chu)了(le)設(she)置(zhi)互(hu)鎖(suo)保(bao)護(hu)外(wai),每(mei)個(ge)操(cao)縱(zong)控(kong)製(zhi)裝(zhuang)置(zhi)都(dou)應(ying)設(she)置(zhi)緊(jin)急(ji)斷(duan)電(dian)開(kai)關(guan),包(bao)括(kuo)手(shou)電(dian)門(men)、便攜式控製裝置。
(2)檢查起重機上有無總電源接觸器,所有機構的動力電源必須全部從總電源接觸器的出線端引接。
通電試驗:操作緊急斷電開關,總電源接觸器動作,切斷所有機構的總電源,所有機構運行停止。
(3)檢查緊急斷電開關的結構形式,應符合緊急斷電開關非自動複位及複位方式的規定,並且複位時不應同時接通機構總電源。
2.操作試驗
緊急斷電開關應在操作後通過齧合或鎖定保持,不能自動複位;複fu位wei動dong作zuo應ying由you觸chu動dong緊jin急ji斷duan電dian開kai關guan本ben身shen產chan生sheng,而er不bu是shi觸chu動dong其qi他ta按an鈕niu。複fu位wei後hou,給gei機ji構gou下xia達da動dong作zuo指zhi令ling,機ji構gou不bu應ying產chan生sheng動dong作zuo。隻zhi有you觸chu動dong啟qi動dong按an鈕niu,接jie通tong電dian源yuan後hou,機ji構gou才cai能neng接jie受shou指zhi令ling產chan生sheng動dong作zuo。
若能同時滿足上述要求,緊急斷電開關可判定為合格。
在(zai)檢(jian)驗(yan)過(guo)程(cheng)中(zhong),緊(jin)急(ji)斷(duan)電(dian)開(kai)關(guan)能(neng)不(bu)能(neng)自(zi)動(dong)複(fu)位(wei),這(zhe)一(yi)點(dian)大(da)家(jia)都(dou)會(hui)注(zhu)意(yi)到(dao)。容(rong)易(yi)忽(hu)略(lve)的(de)是(shi),緊(jin)急(ji)斷(duan)電(dian)開(kai)關(guan)複(fu)位(wei)方(fang)式(shi)和(he)複(fu)位(wei)後(hou),不(bu)應(ying)接(jie)通(tong)總(zong)電(dian)源(yuan)這(zhe)2項要求,常見的緊急斷電開關的結構形式大致有以下3類:
a. 蘑菇頭型開關;
b. 可鎖定型按鈕開關,複位可通過觸發與互鎖的啟動按鈕進行;
c. 普通型(不能鎖定)按鈕開關。
對於c型開關,它不能鎖定,且解除急停的同時接通了總電源,很容易判斷為不合格。
對於b型(xing)開(kai)關(guan),它(ta)能(neng)切(qie)斷(duan)機(ji)構(gou)總(zong)電(dian)源(yuan),且(qie)不(bu)能(neng)自(zi)動(dong)複(fu)位(wei),很(hen)多(duo)使(shi)用(yong)單(dan)位(wei)工(gong)作(zuo)人(ren)員(yuan),包(bao)括(kuo)一(yi)些(xie)檢(jian)驗(yan)人(ren)員(yuan)也(ye)會(hui)經(jing)常(chang)下(xia)錯(cuo)結(jie)論(lun),認(ren)為(wei)合(he)格(ge)。但(dan)這(zhe)種(zhong)開(kai)關(guan)的(de)複(fu)位(wei)方(fang)式(shi)不(bu)符(fu)合(he)要(yao)求(qiu),並(bing)且(qie)複(fu)位(wei)的(de)同(tong)時(shi)接(jie)通(tong)了(le)總(zong)電(dian)源(yuan),所(suo)以(yi)為(wei)不(bu)合(he)格(ge)。
對於a型開關,它能切斷機構總電源、不能自動複位、複(fu)位(wei)由(you)觸(chu)動(dong)開(kai)關(guan)本(ben)身(shen)產(chan)生(sheng),這(zhe)幾(ji)個(ge)要(yao)求(qiu)都(dou)滿(man)足(zu),但(dan)還(hai)不(bu)能(neng)判(pan)定(ding)該(gai)開(kai)關(guan)合(he)格(ge),還(hai)要(yao)試(shi)驗(yan)該(gai)開(kai)關(guan)複(fu)位(wei)的(de)同(tong)時(shi)能(neng)否(fou)接(jie)通(tong)總(zong)電(dian)源(yuan),不(bu)能(neng)接(jie)通(tong)則(ze)為(wei)合(he)格(ge),能(neng)接(jie)通(tong)則(ze)為(wei)不(bu)合(he)格(ge)。
總zong之zhi,緊jin急ji斷duan電dian開kai關guan作zuo為wei重zhong要yao的de檢jian驗yan項xiang目mu,它ta的de合he格ge與yu否fou直zhi接jie關guan係xi到dao起qi重zhong機ji整zheng體ti結jie論lun的de判pan定ding,與yu安an全quan使shi用yong密mi切qie相xiang關guan,必bi須xu詳xiang細xi了le解jie國guo家jia標biao準zhun中zhong的de相xiang關guan規gui定ding,檢jian驗yan時shi通tong過guo認ren真zhen觀guan察cha和he一yi係xi列lie的de試shi驗yan才cai能neng作zuo出chu正zheng確que結jie論lun。
手機版|