據不完全統計,水泥廠的風機發生振動異常的故障率最高時達58.6%.由於振動將造成風機運行不平衡,其中.軸承緊定套配合調整失當,會導致軸承異常溫升和振動 。
如(ru)某(mou)水(shui)泥(ni)廠(chang)在(zai)設(she)備(bei)維(wei)修(xiu)期(qi)間(jian)更(geng)換(huan)了(le)風(feng)機(ji)輪(lun)葉(ye)。輪(lun)葉(ye)兩(liang)側(ce)用(yong)緊(jin)定(ding)套(tao)與(yu)軸(zhou)承(cheng)座(zuo)軸(zhou)承(cheng)固(gu)定(ding)配(pei)合(he)。重(zhong)新(xin)試(shi)車(che)就(jiu)發(fa)生(sheng)自(zi)由(you)端(duan)軸(zhou)承(cheng)高(gao)溫(wen),振(zhen)動(dong)值(zhi)偏(pian)高(gao)的(de)故(gu)障(zhang),拆(chai)開(kai)軸(zhou)承(cheng)匝(za)上(shang)蓋(gai),手(shou)動(dong)慢(man)速(su)回(hui)轉(zhuan)風(feng)機(ji),發(fa)現(xian)處(chu)於(yu)轉(zhuan)軸(zhou)某(mou)一(yi)特(te)定(ding)位(wei)置(zhi)的(de)軸(zhou)承(cheng)滾(gun)子(zi),在(zai)非(fei)負(fu)荷(he)區(qu)亦(yi)有(you)滾(gun)動(dong)情(qing)況(kuang).如此可確定軸承運轉間隙變動偏高且安裝間隙可能不足。經測量得知,軸承內部間隙僅為0.04mm,轉鈾偏心達0.08mm;由you於yu左zuo右you軸zhou承cheng跨kua距ju大da,要yao避bi免mian轉zhuan軸zhou撓nao曲qu或huo軸zhou承cheng安an裝zhuang角jiao度du的de誤wu差cha較jiao難nan,因yin此ci,大da型xing風feng機ji采cai用yong可ke自zi動dong對dui心xin調tiao整zheng的de球qiu麵mian滾gun子zi軸zhou承cheng。但dan當dang軸zhou承cheng內nei部bu間jian隙xi不bu足zu時shi.zhouchengneibugundongjianyinshouyundongkongjiandexianzhi,qizidongduixindejinengshouyingxiang,zhendongzhifanerhuishenggao。zhouchengneibujianxisuipeihejinduzhizengdaerjianxiao,wufaxingchengrunhuaqumo,dangzhouchengyunzhuanjianxiyinwenshengerjiangweilingshi,ruozhouchengyunxingchanshengdereliangrengdayuyisandereliangshi,zhouchengwendujihuikuaisupasheng,zheshi,rubujishitingji,zhouchengzhongjiangshaosun,zhouchengneihuanyuzhouzhipeiheguojinshibenlizhongzhouchengyunzhuanyichanggaowendeyuanyin。
處理時,退下緊定套,重新調整軸與內環的配合緊度,更換軸承之後的間隙取0.10mm。重新安裝完畢重新啟動風機,軸承振動值及運轉溫度均恢複正常。
軸承內部間隙太小或機件設計製造精度不佳,均是分機軸承運轉溫度偏高的主因,為方便風機設備的安裝;拆修和維護.一般在設計上多采用緊定套軸承錐孔內環配合之軸承座軸承,然而也易因安裝程序上的疏忽而發生問題.尤其是適當間隙的凋整。軸承內部間隙太小.運轉溫度急速升高:軸承內環錐孔與緊定套配合太鬆,軸承易因配合麵發生鬆動而於短期內故障燒損。
手機版|
關注公眾號|

下載手機APP