固態高頻焊機循環軟水冷卻體係(風—水冷卻器)
GPKL-Ⅱ型循環軟水冷卻體係采用閉式冷卻塔結構,冷卻用軟水在密封水箱及冷卻管道中流動,由頂置風機+噴淋水方法冷卻內循環軟水,其工作原理為:利li用yong水shui蒸zheng騰teng時shi吸xi收shou熱re量liang的de原yuan理li使shi被bei冷leng卻que軟ruan水shui冷leng卻que。噴pen淋lin水shui貯zhu於yu冷leng卻que塔ta底di部bu,軟ruan水shui在zai閉bi式shi冷leng卻que塔ta的de散san熱re盤pan管guan內nei進jin行xing關guan閉bi循xun環huan,噴pen淋lin水shui由you噴pen淋lin體ti係xi泵beng經jing水shui分fen配pei體ti係xi和he噴pen淋lin嘴zui噴pen淋lin在zai盤pan管guan表biao麵mian,一yi部bu分fen水shui被bei蒸zheng騰teng吸xi走zou熱re量liang,從cong而er降jiang低di管guan內nei軟ruan水shui的de溫wen度du。熱re空kong氣qi中zhong的de水shui和he未wei蒸zheng騰teng的de水shui被bei擋dang水shui板ban截jie住zhu並bing流liu經jingPVC熱交換層,PVC交換層中的水被流過的空氣冷卻,溫度降低,落入冷卻塔底部。
適用範圍:60kW~1200kW感應加熱電源。
Circulation Soft Water Cooling System (air-water cooler)
Model GPKL-Ⅱcirculation soft water cooling system adopts closed cooling tower structure. Cooling soft water flow in sealed water tank and cooling pipes. The inner circulation soft water is cooled by overhead fan and water-spray method using the principle of absorbing heat when evaporation. The spray water store at the bottom of cooling tower, soft water circulate inside the closed cooling tower’s heat dissipation pipe, spray-water spray at pipes’ surface by spray-water distribution system and sprayer through spray system, some heat is taken by dissipation and soft water temperature inside the pipe go down accordingly. The cut board stops water in hot air and undissipated water, make them flow through PVC heat exchange layer, the water in the layer is cooled by air, then temperature goes down and fall down to the bottom of the tower.
Apply range: 60kW~1200kW induction heating power supply.